阐述了现有显微注射系统的结构组成与功能特征,介绍了自动化显微注射技术的国内外研究现状。分析了显微注射中各项自动化操作研究的技术组成及其优缺点,涉及图像处理、微机械加工、智能材料、自动控制、气动、激光与计算机等技术或方法。指出了研究基于手工细胞注射技术路线的全自动显微注射技术的关键问题和困难。展望了自动化显微注射技术的发展方向,并从三方面简要介绍了各方向的研究进展,包括自动化显微注射系统结构、微注射针进针机构和基于仿生微通道的微注射量精确控制技术。

Abstract:

The structure components and function features of the existing microinjection system are expatiated,and the oversea and home research status of the automatic microinjection techno-logy is summarized.With the technologies of the image process,micro machine manufacture,smart material,automatic control,pneumatic,laser and computer,and other methods,the technology components,merits and demerits of the auto manipulation in microinjection are analyzed in detail.The key issues and difficulties of the full automatic microinjection technology based on the manual cell injection technology are pointed out.The development direction of the automatic microinjection technology is briefly presented,the research progress is introduced from three aspects,i.e.the automatic microinjection system,needle inserting system of the microinjection needle and microinjection precision control technology based on the biomimetic micro-channel.

参考文献

[1]GORDONJ W,SCANGOS G A,PLOTKI N D J,et al.Ge-netic transformation of mouse embryos by microinjection of pu-rified DNA[J].Proc Natl Acad Sci Genetics,1980,77(12):7380-7384.

[2]ROBL J M,WANG Z,KASI NATHAN P,et al.Transgenicani mal production and ani mal biotechnology[J].Theriogeno-logy,2007,67(1):127-133.

[3]王洪才,马巍,王军.转基因技术研究进展及在动物生产中的应用[J].中国奶牛,2008,5:29-32.

[4]田桂中.自动化细胞注射中微操作与微注射技术及实验研究[D].南京:南京理工大学,2008.

[5]AMMI M,FERREIRA A.Robotic assisted micro-manipula-tion systemusing virtual fixtures and metaphors[C]//Proceedings of the IEEEInternational Conference on Robotics andAutomation.Roma,Italy,2007:454-460.

[6]YAMAMOTO H,SAMO T.Study of micromanipulation usingstereoscopic microscope[J].IEEE Transcations on Instrumen-tation and Measurement,2002,51(2):182-187.

[7]SANO T,YAMAMOTO H.Multi agent micromanipulationsystem[C]//Proceedings of the IEEE International Work-shop on I maging Systems and Techniques.Niagara Fall City,Niagara,2005:75-78.

[8]KALLIO P,ZHOU Q,LI ND M,et al.Position control of a3DOF piezohydraulic parallel micromanipulator[C]//Pro-ceedings of the IEEE/RSJ International Conference on Intelli-gent Robots and Systems.Victoria,Canada,1998:770-775.

[9]TANIKAWA T,ARAI T.Development of a micro-manipulationsystemhaving a two-finger micro-hand[J].IEEE Transactions onRobotics and Automation,1999,15(1):152-162.

[10]HOSHI NO K,TRITEYAPRASERT S,MATSUMOTO K,et al.Electrowetting-based pico-liter liquid actuation in aglass-tube microinjector[J].Sensors and Actuators:A,2004,114:473-477.

[11]SUN Y,WAN K T,ROBERTS K P,et al.Mechanical pro-perty characterization of mouse zona pellucida[J].IEEETransactions on Nanobioscience,2003,2(4):279-286.

[12]MATTOS L,GRANT E,THRESHER R.Semi-automatedblastocyst microinjection[C]//Proceedings of the IEEE In-ternational Conference on Robotics and Automation.Orlando,Florida,2006:1780-1785.

[13]ZHANG XJ,ZAPPE S,BERNSTEI N R W,et al.Microma-chined silicon force sensor based on diffractive optical encodersfor characterization of microinjection[J].Sensors and Actua-tors:A,2004,114:(2/3)197-203.

[14]TAN K K,NG S C.Computer-controlled piezoactuator forcell manipulation[J].IEEE Proc-Nanobiotechnology,2003,150(1):16-21.

[15]DHOLAKI A K,REECE P.Optical micromanipulation takeshold[J].Nanotoday,2006,1(1):18-27.&?

[16]EDIZ K,OLGAC N.Microdynamics of the piezo-driven pi-pettes in ICSI[J].IEEE Transactions on Biomedical Engi-neering,2004,51(7):1262-1268.

[17]HOSOKAWA H,IGUCHI S,YASUKUNI R,et al.Genedelivery processin a single ani mal cell after femtosecondlasermicroinjection[J].Applied Surface Science,2009,255(24):9880-9884.

[18]SAITO T,MUGURUMA H,MABUCHI K.Photodynamicassistance increases the efficiency of the process of microinjec-tionin ani mal cells[J].Biotechnology Letters,2002,24(4):309-314.

[19]卢桂章,张建勋,赵新.面向生物工程实验的微操作机器人[J].南开大学学报(自然科学),1999,32(3):42-46.

[20]孙明竹,赵新,卢桂章.基于离焦的微操作机器人系统光轴方向深度测量[J].物理学报,2009,58(9):6248-6257.

[21]刘天军.数字化细胞微注射技术及其应用研究[D].南京:南京理工大学,2004.

[22]张灵.DNA超微注射量精密控制技术的研究[D].广州:广东工业大学,2004:56-67,86-99.

[23]王自强,王浩威,席时权,等.微束激光基因转移仪的研制[J].自动化仪表,2006,27(8):18-21.

[24]李银妹.利用光镊技术演示光的自旋角动量[J].物理实验,2007,27(12):6-10.

[25]于保军,杨志刚,周广禄.基于TMS320DM642和S3C2410的细胞微量注射装置控制系统[J].光学精密工程,2008,16(8):1500-1507.

[26]孙明磊,宗光华,余志伟,等.基于图像分析的显微视觉自动聚焦系统[J].北京航空航天大学学报,2005,31(2):192-196.&?

基本信息:

中图分类号:Q-33

引用信息:

[1]田桂中,陈涛,王淑妍,等.生物工程中自动化显微注射技术研究进展[J].微纳电子技术,2011,48(08):536-542.

基金信息:

国家自然科学基金资助项目(51005108);; 江苏科技大学人才引进基金资助项目(35020808)

发布时间:

2011-08-15

出版时间:

2011-08-15

检 索 高级检索

引用

GB/T 7714-2015 格式引文
MLA格式引文
APA格式引文